Contactar Proveedor? Proveed
hania Yang Ms. hania Yang
¿Qué puedo hacer por ti?
Contactar Proveedor

Changchun New Industries Optoelectronics Technology Co., Ltd.

Changchun New Industries Optoelectronics Technology Co., Ltd.
I agree Bossgoo.com will authorize the transaction payment on Bossgoomall.com. Bossgoomall.com is a subsidiary of Bossgoo.com group, Please rest assured to trade.
I agree
HomeLista de ProductosEspectrómetroEspectrómetro de fluorescenciaEspectrómetro de fluorescencia de escritorio hiperfino

Espectrómetro de fluorescencia de escritorio hiperfino

Payment Type:
T/T,Western Union
Incoterm:
EXW
Min. Order:
1 Piece/Pieces
Delivery Time:
30 Days
Share:
  • DDescripción
Overview
Supply Ability & Additional Informations

Tipo de PagoT/T,Western Union

IncotermEXW

Plazo de entrega30 días

CNI lanzó la instrumentación de espectroscopia de fluorescencia con las características de análisis rápido y medición precisa, generalmente se usa en cristal, elementos de tierras raras y otra detección de espectro de fluorescencia. Basado en el principio del espectrofotómetro de fluorescencia, el análisis y la medición del espectro de fluorescencia es especial en alta sensibilidad, fuerte selectividad, micro muestras, operación simple, etc.

CNI proporciona espectrómetro de fluorescencia UV muchos y muchos tipos de accesorios de análisis de espectro, como filtro óptico, medidor de potencia láser, gafas láser, láser de calibración de espectro, lámpara de tungsteno, fuente de luz halógena, placa de protección de seguridad láser, etc.

Caracteristicas

  • Alta sensibilidad y precisión
  • FluSys-405: <0,5 nm
  • FluSys-532: <0,5 nm
  • Se adapta a varias aplicaciones
  • Rango de longitud de onda y resolución personalizados
  • Descarga de soporte para Spectral Analysis 5.0

Aplicaciones

  • Análisis espectral de fluorescencia de cristal
  • Análisis espectral de fluorescencia de análisis de elementos de tierras raras
  • Análisis de la calidad del agua
  • Control T urbidez
  • Análisis de gasolina
  • Análisis de ADN

Componentes básicos

  • FPB-405/532 Fluorescencia Investigacion
  • 4 05/532 láser de fibra acoplada
  • Espectrómetro de fibra : Aurora4000
  • Unidad de procesamiento de datos para PC
  • Interfaz hombre-máquina

Especificaciones

Laser

Wavelength (nm)

405±5 (other wavelengths can be customized)

532±1 (other wavelengths can be customized)

Mode

Near TEM00

TEM00

Power stability (pk-pk, 4 hours)

<1%,3%,5%

<1%,3%,5%

Operating mode

CW

CW

Warm-up time (minutes)

<5

<10

Operating temperature (℃)

10-35

10-35

Expected lifetime (hours)

10000

10000

Warranty

1 year

1 year

Espectrómetro

Wavelength range

405-850 nm
(spectrometer wavelength range and resolution can be customized)

532-1100 nm
(spectrometer wavelength range and resolution can be customized)

Optical resolution (nm)

<0.5 nm FWHM

Pixelspixels

3648

Pixels size

8 μmx 200 μm

Dimensions (mm)

149x 105x 46

Weight (g)

840

Signal-to-noise ratio

300:1

Integration time

4ms-10s

Power consumption

450 mA@ 5V DC

Data transfer speed

Full scans into memory every 4 milliseconds with USB 2.0
Full scans into memory every 18 milliseconds with USB 1.1

Inputs/outputs 5 inputs and 5 outputs (opto-isolator inputs/outputs)
Analog channels One 12 analog input one 12 analog output
Connector 30pin
Sonda de fluorescencia

Excitation wavelength (nm)

405 (Spectrum linewidth ~1 nm)

532 (Spectrum linewidth ~1 nm)

Probe focus length (mm)

7.5

Main material of probe

Black anodised aluminium, 111*38*14.8mm head 38mm long

Fiber configuration

Two single fiber (100 um excitation fiber, 200 um receiving optical fiber) N.A.=0.22, SMA905 connector, PVC/metal sheath; 1 m length

Filter effect

Can be completely filtered out of the stray light received, and eliminate the quartz fiber generated background scattering
(O.D.> 5 @ laser wavelength)

Working temperature (℃)

0-40

Connection port

SMA 905 connector

Software

Optical spectrum analysis

Spectrum Analysis Software

Operating system

Windows XP/ Win7 (32 bits or 64 bits)

Característica

  • Dimensiones: 420x 272x 160 mm
  • Fuente láser de excitación de 405/532 nm con potencia ajustable y estable
  • Medición simple, rápida y fácil operación
  • muestreo flexible y estable, diversas formas de análisis de muestras
  • fuente de alimentación externa (carga), con cargador montado en el vehículo
  • a prueba de polvo, impermeable, antivibración, interferencia antideslumbrante en el uso de entornos salvajes

Accesorios

Fluorescence spectroscopy instrumentation 11111111Uv Fluorescence Spectrometer 111111Fluorescence spectrometer diagram

111 Filtro óptico 11111111111111111 Medidor de potencia láser 1111111111111 1 1 Gafas láser


Certificación

near infrared spectrometer

Información de la empresa

Changchun New Industries (CNI), fundada en 1996, ubicada en Changchun, CHINA, es un fabricante líder de sistemas láser de diodo y de estado sólido. CNI posee un servicio responsable y confiable, así como productos de calidad con diseño compacto, alta confiabilidad y excelente desempeño. Los productos se utilizan ampliamente para investigación científica, fabricación de equipos, experimentos biomédicos, medición de precisión, entretenimiento, comunicación por radar, procesamiento de materiales, control de procesos, detección en línea, equipos de investigación y otros campos.

Exposiciones

PRODUCTOS POR GRUPO : Espectrómetro > Espectrómetro de fluorescencia

Descargar
Contactar proveedor
  • *A:
    Ms. hania Yang
  • *Mensaje:
    Su mensaje debe ser de entre 20 a 8,000 caracteres.
hania Yang

Ms. hania Yang

SEND INQUIRY

  • Número de Teléfono:

    86-0431-87025016

  • Fax:

    86-0431-87020258

  • E-mail:

    yangsh@cnilaser.com

Inicio

Phone

Información de la Empresa

solicitar